SPECIFICATIONS:
Number of turns (as marked on the former): 700 turns 0.9mm diameter enamelled copper.
Maximum steady current: 3 amps. Peak current (for up to 30 sec.max.): 5 amps.
CAUTION: During any experiment, be careful that the coil does not overheat during use.
If the winding is too hot to touch with the hand, it means the coil internally will be overheated and it must be turned off immediately before damage occurs.
The Air Cored Solenoid can also be used for magnetising and demagnetising or other general purpose solenoid work.
Physical size: 167x68x77mm (LxWxH)